FPT-6310流量传感器 美国OMEGA FPT-6310
FPT-6310
流量与液位 » 涡街流量计和皮托管 » 高精度皮托管 » FPT-6300
适用于接液龙头装置的高精度皮托管
FPT-6300
Up to ±1% of Rate Accuracy
Wet Tap Assembly Permits Installation/Removal
in Live Lines
Very Low Pressure Drop
Low Maintenance
For Clean, Low Viscosity Liquids, Gases
and Steam
产品描述
The FPT-6300 averaging pitot tube is similar to the FPT-6100 in performance, but features a wet-tap assembly which permits installation and removal of the sensor in pressurized lines without process shutdown. The weld coupling is first welded into place, then the ball valve and packing are put in place. Next, a drill is used to drill out the pipe. The drill is partially withdrawn and the ball valve is closed. The drill may then be completely removed and the sensing tube partially installed in the assembly. Finally, the ball valve is opened and the sensing tube is inserted into the flowstream. The FPT-6300 is ideal for retrofits on critical flowstreams.
Complete this questionnaire to size the Pitot tube for your application.
SPECIFICATIONS
Accuracy: Up to 1% of rate (see sizing). (Accuracy stated is for use in schedule 40 pipe. If used in schedule 80 pipe, add 1% to accuracy or request special construction)
Repeatability: ±0.1% of rate
Max Temperature and Pressure: 88°C(190°F) at 150 psig operating; 88°C(190°F) at 100 psig during insertion/removal
Unrecoverable Pressure Drop (inches H2O): = DP x (CP/D)
where: DP = generated differential pressure (inches H2O)
CP = pressure loss coefficient
= 0.296 for 3⁄8" diameter probe
= 0.387 for ½"
= 0.757 for ¾"
= 0.945 for 1"
D = inside pipe diameter (inches)
Wetted Parts: carbon steel weld coupling and pipe fittings, brass ball valve and packing, and Zytel ferrule. For 316 SS construction, consult Flow Engineering Dept.
Sizing Equations
1. Any Liquid: ΔP (inH2O) = Q2(GPM) x Sf / K2 x D41 x 32.14
2. Steam or Any Gas (steam requires min ΔP of 10" H2O): ΔP (in. H2O) = Q2(lb/hr) / K2 x D41 x ρ x 128,900
3. Any Gas: ΔP (inH2O)= Q2 (scfm) x SS x (T + 460) / K2 x D41 x P x 16,590
Where:
ΔP = differential pressure (in inches H2O)
Q = flowrate
K = flow coefficient (see "how to order")
D1 = inside diameter of line size (in inches for square and rectangular ducts use): D1 = √(4 x height x width / Π)
P = static line pressure (psia)
T = temperature (in °F)
ρ = density of medium (in pounds per cubic foot)
Sf = Sp. Gr. at flowing conditions
Ss = Sp. Gr. at 15°C (60°F)
NOTE: Use of these equations for liquids yields an accuracy of ±2% of rate. When used for steam, accuracy is ±10% of rate (when steam tables are used). Gas equation yields ±2% of rate accuracy from 21 to 204°C (70 to 400°F) and 0 to 150 psig (when gas is not near its critical point). A ±1% of rate accuracy requires the use of more precise equations which account for shift in K with change in flowrate, gas compressibility, etc. Request a precision flow calibration sheet and please supply the following data: name of fluid, specific gravity, pressure, temperature, inside pipe diameter, viscosity, steam quality, degrees superheat, and ratio of specific heat at constant pressure to that at constant volume (for gas velocities approaching 500 fps).
注: Comes complete with operator's manual.
产品编号 产品描述
FPT-6310 1" Nominal Line Size
FPT-6312 11/4 " Nominal Line Size
FPT-6315 11/2 " Nominal Line Size
FPT-6320 2" Nominal Line Size
FPT-6325 21/2 " Nominal Line Size
FPT-6330 3" Nominal Line Size
FPT-6335 31/2 " Nominal Line Size
FPT-6340 4" Nominal Line Size
FPT-6350 5" Nominal Line Size
FPT-6360 6" Nominal Line Size
FPT-6380 8" Nominal Line Size
FPT-6381 10" Nominal Line Size
FPT-6382 12" Nominal Line Size
FPT-6383 14" Nominal Line Size
FPT-6384 16" Nominal Line Size
FPT-6385 18" Nominal Line Size
FPT-6386 20" Nominal Line Size
FPT-6387 24" Nominal Line Size
FPT-6388 30" Nominal Line Size
FPT-6310
FPT-6312
FPT-6315
FPT-6320
FPT-6325
FPT-6330
FPT-6335
FPT-6340
FPT-6350
FPT-6360
FPT-6380
FPT-6381
FPT-6382
FPT-6383
FPT-6384
FPT-6385
FPT-6386
FPT-6387
FPT-6388
FPT-6310
FPT-6310流量传感器 美国OMEGA FPT-6310衍生阅读
FPT-6310流量传感器 美国OMEGA FPT-6310相关产品