img02
img05
产品[

DP6000-6R3美国OMEGA DP6000-6R3

]资料
如果您对该产品感兴趣的话,可以 sendmsg
产品名称: DP6000-6R3美国OMEGA DP6000-6R3
产品型号: DP6000-6R3
产品展商: 其它品牌
产品文档: 无相关文档
简单介绍
DP6000-6R3美国OMEGA DP6000-6R3由美国omega原厂渠道的深圳鑫博恒业科技有限公司特价提供,DP6000-6R3美国OMEGA DP6000-6R3精度高,寿命长,DP6000-6R3美国OMEGA DP6000-6R3是值得信赖的精密仪表.


DP6000-6R3美国OMEGA DP6000-6R3的详细介绍

DP6000-6R3美国OMEGA DP6000-6R3

DP6000-6R3

1/8 DIN过程面板仪表
DP6000 Series
1/8 DIN过程面板仪表
模块化的USB,RS232,RS485串行通信选项和继电器
0到20毫安,4至20毫安,0至5V,1至5V,10V的输入和±
NEMA 4X(IP65)前
通用的85到265 VAC或12 / 24 VDC输入功率
大型双行6-character显示,15和12毫米(0.60和0.46)
阳光下可读的显示模式
孤立的24 VDC @ 200毫安发射器电源标准
可编程显示器和功能键
32点,平方根,指数或线性化
的Modbus RTU通信协议标准?
使用自由软件,监控和编程


The DP6000 Series meter boasts specifications and functionality that clearly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced signal input conditioning functions, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the DP6000. Sunlight readable display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/ minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off. The user friendly dual-line display makes the DP6000 easy to set up and program. No jumpers to set for input selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6000 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly.
General Specifications
Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display: 15 mm (0.60") high
Lower Display: 12 mm (0.46") high
Display Intensity: 8 intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
Front Panel: NEMA 4X (IP65)
Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
Noise Filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak)/ min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max
Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Overvoltage Category: Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range: -40 to 65°C (-40 to 149°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight: 269 g (9.5 oz)
注释: Comes complete with 2 side mounting brackets and operator’s manual.


产品型号说明
(1)
DP6000 -
选项描述
(1) Output
选择
6R0 代表 Process panel meter
6R2 代表 Process panel meter with 2 relays
6R3 代表 Process panel meter with 4 to 20 mA output
6R4 代表 Process panel meter with 4 relays
6R5 代表 Process panel meter with 2 relays and 4 to 20 mA output
6R7 代表 Process panel meter with 4 relays and 4 to 20 mA output
7R0 代表 Process panel meter
7R2 代表 Process panel meter with 2 relays
7R3 代表 Process panel meter with 4 to 20 mA output
6H0 代表 Process panel meter
6H2 代表 Process panel meter with 2 relays
6H3 代表 Process panel meter with 4 to 20 mA output
7H0 代表 Process panel meter
7H2 代表 Process panel meter with 2 relays
7H3 代表 Process panel meter with 4 to 20 mA output 

DP6000-6R3 

DP6000-6R3美国OMEGA DP6000-6R3相关产品


产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!


Copyright© 2003-2024  深圳市鑫博恒业科技有限公司版权所有     
联系电话:0755-82768776  0755-82736276  传真号码:0755-83041664
公司地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口) Email:info@xb5j.cn  邮编:518031

粤ICP备09037369号  

 

粤公网安备 44030402001380号