img02
img05
产品[

SYS/FTBG-112/FLSC-C3流量计 美国omega

]资料
如果您对该产品感兴趣的话,可以 sendmsg
产品名称: SYS/FTBG-112/FLSC-C3流量计 美国omega
产品型号: SYS/FTBG-112/FL
产品展商: 其它品牌
产品文档: 无相关文档
简单介绍
SYS/FTBG-112/FLSC-C3流量计 美国omega由美国omega原厂渠道的深圳鑫博恒业科技有限公司特价提供,SYS/FTBG-112/FLSC-C3流量计 美国omega精度高,SYS/FTBG-112/FLSC-C3流量计 美国omega是值得信赖的流量仪表


SYS/FTBG-112/FLSC-C3流量计 美国omega的详细介绍


SYS/FTBG-112/FLSC-C3流量计 美国omega

燃气轮机和变送器系统,带ATEX外壳
SYS/FTBG-100 Series
1年保修 新产品! CE
燃气轮机和变送器系统,带ATEX外壳
SYS/FTBG-100 Series:燃气轮机和变送器系统,带ATEX外壳
Outstanding Accuracy
Hybrid Ceramic Bearings for Superior Life
DC or AC (Optional) Power
Pulse and Analog Output
Optional Hi and Lo Alarms
Factory Configured
Windows? Configuration Software (Included)
Nist Certificate Standard
OMEGA’s high accuracy Gas Turbine Series measures the volumetric flow of gas through a pipeline. Gas flowing through the meter turns the turbine rotor at an angular velocity which is proportional to the velocity of the gas being measured. As the turbine rotor turns, the rotor blades pass a non-intrusive pickup coil that generates an electrical signal, referred to as a pulse. Each pulse represents a specific volume of gas (i.e. ACF/AM3). The totalization of these pulses results in the total volumetric flow. The total volume can be converted to mass flow total (SCF or NM3) using reference conditions and base density, or by applying various correction techniques. Standard calibrations for these gas turbine systems are performed at a reference density of 0.1 lb/Ft3. A 10-point calibration certificate (traceable to NIST or other recognized national laboratory) is supplied with each meter. Standard calibration includes a calculated K-factor for gas that is derived from a 10-point NIST calibration for water. Calibrations at customer’s actual operating densities can be performed with special order. OMEGA’s gas turbine flowmeters offer high accuracy measurement of gases for a wide variety of applications, including fiscal measurement, plant cost allocation, energy consumption/conservation, etc. These gas turbine systems are suitable for all non-corrosive gases such as natural gas, air and nitrogen. Special versions of this series are available for use on corrosive gases, such as “off-gas” and feature NACEMR175 trim and self-lubricated ceramic ball bearings. Contact OMEGA for further details. An OMEGA? gas turbine flowmeter should be chosen so that it is operated within its most accurate range. The capacity of a turbine flowmeter is based on the actual volumetric flow rate and is expressed as actual cubic feet (ACF) or actual cubic meters (AM3). The lower limit of operation is a function of the gas density and velocity.
SPECIFICATIONS (TURBINE)
Over-range: 150% of maximum flow (intermittently)
Turn Down Range: Dependent on gas density at user’s operating conditions
Linearity: ±1% of reading typical
Repeatability: ±0.25% over tabulated repeatable range
Available Temperature Range: -157 to 149°C (-250 to 300°F) continuous
End Fittings (Standard): NPT
Bearing Styles: Self-lubricating, ceramic hybrid ball bearings
Materials: 316/316L dual rated stainless steel with 17.4 pH rotor
SPECIFICATIONS (SIGNAL CONDITIONER)
Input Signal Type: MCP pickup
Input Frequency Range: 0.2 Hz to 4 KHz
Signal Level: 10 mV rms to 30 Vdc
Power Supply: 13 to 30 Vdc standard, 100 to 240 Vac (-AC) (optional), reverse polarity protection
Analog Output: 4 to 20 mA, 1 to 5V, 24 mA overflow condition (dip switch selectable)
Load Resistance: Max 650 ù @ 24 Vdc
Accuracy: °0.02% of full scale
Temperature Drift: 40 ppm/°C
Pulse Output: 0 to 5V Recommended Minimum Load
Resistance: 50 Kù
Pulse Scaling: Divide by 1,10,100 per flow unit of measure
Hi/Lo Alarm (Optional): Relay (2A, 30 Vdc), 0 to 5V, open collector (0.5A, 30V)
Communications: RS232 port for configuration and diagnostics
Linearization: Up to 20 points
Operating Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 0 to 90% non-condensing
Enclosure: Extruded aluminum explosion-proof ATEX
Port: 3/4-14 NPT
Regulatory: CE compliant

产品型号  产品描述
Gas Turbine and Signal Conditioner Systems
SYS/FTBG-101/FLSC-C3  0.25' Meter, 0.5 NPT, 30° Blade Angle
SYS/FTBG-102/FLSC-C3  0.25' Meter, 0.5 NPT, 15° Blade Angle
SYS/FTBG-103/FLSC-C3  0.375' Meter, 0.5 NPT, 30° Blade Angle
SYS/FTBG-104/FLSC-C3  0.375' Meter, 0.5 NPT, 15° Blade Angle
SYS/FTBG-105/FLSC-C3  0.625' Meter, 0.75 NPT, 30° Blade Angle
SYS/FTBG-106/FLSC-C3  0.625' Meter, 0.75 NPT, 15° Blade Angle
SYS/FTBG-107/FLSC-C3  0.75' Meter, 0.75 NPT, 30° Blade Angle
SYS/FTBG-108/FLSC-C3  0.75' Meter, 0.75 NPT, 15° Blade Angle
SYS/FTBG-109/FLSC-C3  1' Meter, 1 NPT, 30° Blade Angle
SYS/FTBG-110/FLSC-C3  1' Meter, 1 NPT, 15° Blade Angle
SYS/FTBG-111/FLSC-C3  1.5' Meter, 1.5 NPT, 30° Blade Angle
SYS/FTBG-112/FLSC-C3  1.5' Meter, 1.5 NPT, 15° Blade Angle
SYS/FTBG-113/FLSC-C3  2' Meter, 2 NPT, 30° Blade Angle
SYS/FTBG-114/FLSC-C3  2' Meter, 2 NPT, 15° Blade Angle
SYS/FTBG-115/FLSC-C3  3' Meter, 3 NPT, 30° Blade Angle
SYS/FTBG-116/FLSC-C3  3' Meter, 3 NPT, 15° Blade Angle
Turbine and Signal Conditioner Systems with Optional Hi/Lo Alarm
SYS/FTBG-101/FLSC-C3-AL  0.25' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-102/FLSC-C3-AL  0.25' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-103/FLSC-C3-AL  0.375' Meter, 0.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-104/FLSC-C3-AL  0.375' Meter, 0.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-105/FLSC-C3-AL  0.625' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-106/FLSC-C3-AL  0.625' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-107/FLSC-C3-AL  0.75' Meter, 0.75 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-108/FLSC-C3-AL  0.75' Meter, 0.75 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-109/FLSC-C3-AL  1' Meter, 1 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-110/FLSC-C3-AL  1' Meter, 1 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-111/FLSC-C3-AL  1.5' Meter, 1.5 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-112/FLSC-C3-AL  1.5' Meter, 1.5 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-113/FLSC-C3-AL  2' Meter, 2 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-114/FLSC-C3-AL  2' Meter, 2 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-115/FLSC-C3-AL  3' Meter, 3 NPT, 30° Blade Angle, signal conditioner includes optional high/low alarm
SYS/FTBG-116/FLSC-C3-AL  3' Meter, 3 NPT, 15° Blade Angle, signal conditioner includes optional high/low alarm
Accessories
FLSC-C3  ±Replacement 4 to 20 mA signal conditioner for gas turbine system only,
FLSC-C3-AL  ±Replacement 4 to 20 mA signal conditioner with optional high/low alarm for gas turbine system only,
FLSC-C-CABLE  ±9-pin D connector to transmitter Molex
OM-CONV-USB  USB to RS232 converter
 


 SYS/FTBG-112/FLSC-C3流量计 美国omega
 

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!


Copyright© 2003-2024  深圳市鑫博恒业科技有限公司版权所有     
联系电话:0755-82768776  0755-82736276  传真号码:0755-83041664
公司地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口) Email:info@xb5j.cn  邮编:518031

粤ICP备09037369号  

 

粤公网安备 44030402001380号